XXH-1005 X-ray Generator 100kv
- Aolong
- China
- 15 days
- 1500pc/year
XXH-1005 100kv X-ray Generator equipped with the seletcted 100 kV glass X-ray insert with the beam angle of 30×360 ° and 25×360 ° option. Under the working voltage of 100kV and focal distance of 600mm, XXH-1005 can penetrate 27mm Q235 steel,
XXH-1005 100kv X-ray Generator is our factory in the full analysis of domestic and foreign related product technical performance indicators, carefully developed and manufactured products, over the years in the domestic and foreign markets by the majority of users praise.
XXH-1005 X-ray Generator is designed and produced under strict quality management system,Its structure, working performance, life and reliability and other technical quality indicators have reached the current advanced level.
XXH-1005 100kv X-ray Generator uses SF6 gas insulation, small volume, light weight. The XXH-1005 machine is composed of console, X-ray generator and low-voltage connecting cable.
POWER SUPPLY CONDITIONS
The AC-mains voltage range spans from 220 to 240 VAC and the frequency is 50Hz.
The improved power factor correction module ensures stable operation, where AC-mains are unstable.
CERTIFICATES
CE(No. 3J190703.DARTQ22, Technical Construction File no. TCF-GGC-190625-064)
Verification to:
Standard: EN61010-1:2101, EN 61326-1: 2013
Related to CE Directive:
2014/35/EU(Low voltage)
2014/30/EU(Electromagnetic Compatibility)
Specifications
Panoramic Portable X-ray Flaw Detector (with ceramic X-ray tube)
Model | Output Voltage (kv) | Input (kw) | Focus (mm) | Beam Angle | Q235 Max. Penetration(mm) | Weight of Generator(kg) | Dimension of Generator(mm) | ||
Cone Target | Flat Target | Cone Target | Flat Target | ||||||
XXGH-2005 | 100~200 | 2.0 | 1.0×3.5 | 30×360° | 25×360° | 24 | 27 | 31 | 290×615 |
XXGH-2505 | 150~250 | 2.5 | 1.0×2.4 | 30×360° | 25×360° | 34 | 37 | 35 | 325×705 |
XXGH-3005 | 170~300 | 3.0 | 1.0×2.3 | 30×360° | 25×360° | 44 | 47 | 43 | 245×715 |
Panoramic Portable X-ray Flaw Detector (with glass X-ray tube)
Model | Output Voltage (kV) | Input (kw) | Focus Size (mm) | Beam Angle | Q235 Max. Penetration(mm) | Weight of Generator(kg) | Dimension of Generator(mm) | ||
Cone Target | Flat Target | Cone Target | Flat Target | ||||||
XXH-1005 | 60~100 | 1.2 | 1.0×3.5 | 30×360° | 25×360° | 4 | 6 | 11.1 | 190×530 |
XXH-1605 | 80~160 | 1.5 | 1.0×3.5 | 30×360° | 25×360° | 12 | 15 | 15 | 225×585 |
XXH-2005 | 100~200 | 2.0 | 1.0×3.5 | 30×360° | 25×360° | 24 | 27 | 21.5 | 285×665 |
XXH-2505 | 150~250 | 2.5 | 1.0×2.4 | 30×360° | 25×360° | 34 | 37 | 33.5 | 320×730 |
XXH-3005 | 170~300 | 3.0 | 1.0×2.3 | 30×360° | 25×360° | 44 | 47 | 40 | 345×830 |
XXH-3205 | 180~320 | 3.2 | 1.0×5.0 | 30×360° | 25×360° | 45 | 50 | 40 | 345×830 |
XXH-3505 | 180~350 | 3.4 | 1.0×5.0 | 30×360° | 25×360° | 52 | 55 | 42.6 | 345×830 |
Directional Portable X-ray Flaw Detector (with glass X-ray tube)
Model | Output Voltage (kV) | Input (kw) | Focus Size (mm) | Beam Angle | Q235 Max. Penetration(mm) | Weight of Generator(kg) | Dimension of Generator(mm) |
XXQ-1005 | 60~100 | 1.2 | 0.8×0.8 | 40° | 8 | 11.1 | 190×530 |
XXQ-1605 | 80~160 | 1.5 | 0.8×0.8 | 40° | 19 | 15.2 | 225×585 |
XXQ-2050 | 100~200 | 2.0 | 1.5×1.5 | 40+5° | 30 | 23 | 285×665 |
XXQ-2505 | 150~250 | 2.5 | 2.0×2.0 | 40+5° | 40 | 35 | 320×730 |
XXQ-3005 | 170~300 | 3.0 | 2.3×2.3 | 40+5° | 50 | 45.5 | 345×830 |
XXQ-3205 | 180~320 | 3.2 | 2.5×2.3 | 40+5° | 55 | 45.5 | 345×830 |
XXQ-3505 | 180~350 | 3.4 | 2.8×3.0 | 40+5° | 60 | 47 | 345×800 |
Directional Portable X-ray Flaw Detector (with ceramic X-ray tube)
Model | Output Voltage (kV) | Input (kw) | Focus Size (mm) | Beam Angle | Q235 Max. Penetration(mm) | Weight of Generator(kg) | Dimension of Generator(mm) |
XXG-1605 | 80~160 | 1.5 | 0.8×0.8 | 40+5° | 19 | 14.5 | 225×550 |
XXG-2005 | 100~200 | 2.0 | 2.0×2.0 | 40+5° | 30 | 18 | 285×615 |
XXG-2505 | 150~250 | 2.5 | 2.0×2.0 | 40+5° | 40 | 30.5 | 320×640 |
XXG-3005 | 170~300 | 3.0 | 2.5×2.5 | 40+5° | 50 | 36.5 | 345×670 |
XXG-3505 | 180~350 | 3.5 | 2.5×2.5 | 40+5° | 60 | 38 | 345×670 |
Convincing inspection solition supplier
More than 50 years, Aolong Group focuses on the Non-destructive Testing Technologies and gives our customers the best inspection solution with the high quality radiographic equipment with simple operation and complete functions.
Global non-destructive testing service pioneer
Our industrial X-ray equipment have been sold to over 60 countries and built our agents and after sale service centers in Europe, U.S, Africa and Asia. We can supply both high quality products and good after sale service.
Packing details
Each product will be packed in cartons or wooden cases (we also accept customers' demands)
Delivery time
1. For sample order, 3-5 working days
2. For mass production, 5-7 weeks (It also depends on the order quantity and design)