XXQ-2505 Ndt Casting Inspection Equipment
- Aolong
- China
- 15 days
- 1500pc/year
XXQ-2505 Ndt Casting Inspection Equipment adopts the selected glass X-ray insert carefully. X-ray insert is the core part of the whole set of machine. The performance and quality of the insert directly determine the quality of the whole set of XXQ-2505 Ndt Casting Inspection Equipment.
The XXQ-2505 ndt inspection equipment consists of three parts: control console, X-ray generator and low-voltage connecting cables.
SOLID AND DURABLE STRUCTURAL DESIGN
The generator of XXQ-2505 Casting Inspection equipment is protected by end ring, which is made of nearly 30mm solid steel and wrapped with rubber to prevent vibration and slipping. The end ring prevents damage to the core components in the event of a collision.
THE CONTROLLER EASY TO CARRY
The volume of the control panel of XXQ-2505 Casting Inspection equipment is 270 ×270× 140mm, weight less than 10kg, very convenient to carry, easy to use in the field.
When the XXQ-2505 ndt inspection equipment breaks down, there will be fault code display, so that the operator can intuitively grasp the fault information and carry out maintenance.
WORKING PRINCIPLE
The XXQ-2505 ndt Casting Inspection equipment is composed of intelligent controller-ray generator, power cable and connecting cable.
1.The controller will consist of the following sections:
Front Panel: LED display, status and failure indicator, touch keyboards (see the introduction of control panel)
Side Panel: power cable socket and connecting cable socket, power switch,key switch, fuse socket, warning lamp and wire connecting terminal of door-machine interlock.
Internal Circuit: power circuit, rectifying circuit, filter circuit, inverter circuit, control circuit and other circuited.
2.The x-ray generator of the XXQ-2505 ndt equipment will consist of the following sections:
X-ray tube, High voltage transformer, Temperature relay, Gas pressure gauge and Cooling
Specifications
Panoramic Portable X-ray Flaw Detector (with ceramic X-ray tube)
Model | Output Voltage (kv) | Input (kw) | Focus (mm) | Beam Angle | Q235 Max. Penetration(mm) | Weight of Generator(kg) | Dimension of Generator(mm) | ||
Cone Target | Flat Target | Cone Target | Flat Target | ||||||
XXGH-2005 | 100~200 | 2.0 | 1.0×3.5 | 30×360° | 25×360° | 24 | 27 | 31 | 290×615 |
XXGH-2505 | 150~250 | 2.5 | 1.0×2.4 | 30×360° | 25×360° | 34 | 37 | 35 | 325×705 |
XXGH-3005 | 170~300 | 3.0 | 1.0×2.3 | 30×360° | 25×360° | 44 | 47 | 43 | 245×715 |
Panoramic Portable X-ray Flaw Detector (with glass X-ray tube)
Model | Output Voltage (kV) | Input (kw) | Focus Size (mm) | Beam Angle | Q235 Max. Penetration(mm) | Weight of Generator(kg) | Dimension of Generator(mm) | ||
Cone Target | Flat Target | Cone Target | Flat Target | ||||||
XXH-1005 | 60~100 | 1.2 | 1.0×3.5 | 30×360° | 25×360° | 4 | 6 | 11.1 | 190×530 |
XXH-1605 | 80~160 | 1.5 | 1.0×3.5 | 30×360° | 25×360° | 12 | 15 | 15 | 225×585 |
XXH-2005 | 100~200 | 2.0 | 1.0×3.5 | 30×360° | 25×360° | 24 | 27 | 21.5 | 285×665 |
XXH-2505 | 150~250 | 2.5 | 1.0×2.4 | 30×360° | 25×360° | 34 | 37 | 33.5 | 320×730 |
XXH-3005 | 170~300 | 3.0 | 1.0×2.3 | 30×360° | 25×360° | 44 | 47 | 40 | 345×830 |
XXH-3205 | 180~320 | 3.2 | 1.0×5.0 | 30×360° | 25×360° | 45 | 50 | 40 | 345×830 |
XXH-3505 | 180~350 | 3.4 | 1.0×5.0 | 30×360° | 25×360° | 52 | 55 | 42.6 | 345×830 |
Directional Portable X-ray Flaw Detector (with glass X-ray tube)
Model | Output Voltage (kV) | Input (kw) | Focus Size (mm) | Beam Angle | Q235 Max. Penetration(mm) | Weight of Generator(kg) | Dimension of Generator(mm) |
XXQ-1005 | 60~100 | 1.2 | 0.8×0.8 | 40° | 8 | 11.1 | 190×530 |
XXQ-1605 | 80~160 | 1.5 | 0.8×0.8 | 40° | 19 | 15.2 | 225×585 |
XXQ-2050 | 100~200 | 2.0 | 1.5×1.5 | 40+5° | 30 | 23 | 285×665 |
XXQ-2505 | 150~250 | 2.5 | 2.0×2.0 | 40+5° | 40 | 35 | 320×730 |
XXQ-3005 | 170~300 | 3.0 | 2.3×2.3 | 40+5° | 50 | 45.5 | 345×830 |
XXQ-3205 | 180~320 | 3.2 | 2.5×2.3 | 40+5° | 55 | 45.5 | 345×830 |
XXQ-3505 | 180~350 | 3.4 | 2.8×3.0 | 40+5° | 60 | 47 | 345×800 |
Directional Portable X-ray Flaw Detector (with ceramic X-ray tube)
Model | Output Voltage (kV) | Input (kw) | Focus Size (mm) | Beam Angle | Q235 Max. Penetration(mm) | Weight of Generator(kg) | Dimension of Generator(mm) |
XXG-1605 | 80~160 | 1.5 | 0.8×0.8 | 40+5° | 19 | 14.5 | 225×550 |
XXG-2005 | 100~200 | 2.0 | 2.0×2.0 | 40+5° | 30 | 18 | 285×615 |
XXG-2505 | 150~250 | 2.5 | 2.0×2.0 | 40+5° | 40 | 30.5 | 320×640 |
XXG-3005 | 170~300 | 3.0 | 2.5×2.5 | 40+5° | 50 | 36.5 | 345×670 |
XXG-3505 | 180~350 | 3.5 | 2.5×2.5 | 40+5° | 60 | 38 | 345×670 |
Dandong Aolong Radiative Instrument Group Co.,Ltd. occupies 30 thousand square meters, and the construction area is 17 thousand square meters, owning international modern advanced manufacturing conditions and research, manufacture and test facilities. We are the leading radiography manufacturer and service application provider.
Aolong Certificate
ISO9000 International quality system certificate
ISO14001 International environment system certificate
DHSAS18001 International career health & safety management system certificate
CE certificate
Packing details
Each product will be packed in cartons or wooden cases (we also accept customers' demands)
Delivery time
1. For sample order, 3-5 working days
2. For mass production, 5-7 weeks (It also depends on the order quantity and design)