XXQ-3005 X-ray Testing Of Casting Equipment
  • Aolong
  • China
  • 15 days
  • 1500pc/year

XXQ-3005 X-ray Testing Of Casting Equipment can be configured with various models of x ray glass tube heads like 300 kV with the optional beam angle of 40+5 °. Under the working voltage of 300kV and focal distance of 600mm, its penetration can reach up to 50mm (A3 steel) thick.

XXQ-3005 X-ray Testing Of Casting Equipment is mainly used to detect machining parts with or without defects, such as inclusion, white spots, sand holes, cracks, pores, etc., so as to determine whether the workpiece is qualified.

FEATURE:
●Checking the software and hardware itself after start the XXQ-3005 x-ray equipment

●Excellent anti-jamming performance, which can adapt for field operation without power supply, because of the motor supports

●Can adjust exposure parameters with keys ( easy operation.)

●Has the function of Delay time opening HV. Convenient for operator keep away from dangerous field

●Can adjust high voltage slowly for protecting X-ray generator

●Automatically controlling according to 1:1 working and rest operating way, the longest continuous exposure period is 5 minutes.

●Including complete protecting system: over KV, low mA, over mA, over temperature and optical-sound alarming

●Convenient for repairing and maintenance

●Much more Substance for structure designing, much more convenient for local operation

●Time can be changed for±0.3 according to the power supply net to make the exposure more precise


OPTIONS

The right set of accessories is important to make your workflow even smarter. Tube brackets and accessories are available, making the X-ray systems versatile, flexible and suited for most applications.


POWER SUPPLY CONDITIONS OF XXQ-3005 X-ray Testing Of Casting Equipment

The AC-mains voltage range spans from 220 to 240 VAC and the frequency is 50Hz.The improved power factor correction module ensures stable operation, where AC-mains are unstable.


Specifications 

Panoramic Portable X-ray Flaw Detector (with ceramic X-ray tube)

ModelOutput
Voltage
(kv)
Input
(kw)
Focus
(mm)
Beam AngleQ235 Max.
Penetration(mm)
Weight of
Generator(kg)
Dimension of
Generator(mm)
Cone TargetFlat TargetCone TargetFlat Target
XXGH-2005100~2002.01.0×3.530×360°25×360°242731290×615
XXGH-2505150~2502.51.0×2.430×360°25×360°343735325×705
XXGH-3005170~3003.01.0×2.330×360°25×360°444743245×715

Panoramic Portable X-ray Flaw Detector (with glass X-ray tube)

ModelOutput
Voltage
(kV)
Input
(kw)
Focus Size
(mm)
Beam Angle   Q235 Max.
Penetration(mm)
Weight of
Generator(kg)
Dimension of
Generator(mm)
Cone TargetFlat TargetCone TargetFlat Target
XXH-100560~1001.21.0×3.530×360°25×360°4611.1190×530
XXH-160580~1601.51.0×3.530×360°25×360°121515225×585
XXH-2005100~2002.01.0×3.530×360°25×360°242721.5285×665
XXH-2505150~2502.51.0×2.430×360°25×360°343733.5320×730
XXH-3005170~3003.01.0×2.330×360°25×360°444740345×830
XXH-3205180~3203.21.0×5.030×360°25×360°455040345×830
XXH-3505180~3503.41.0×5.030×360°25×360°525542.6345×830

Directional Portable X-ray Flaw Detector (with glass X-ray tube)

ModelOutput Voltage
(kV)
Input
(kw)
Focus Size
(mm)
Beam AngleQ235 Max.
Penetration(mm)
Weight of
Generator(kg)
Dimension of
Generator(mm)
XXQ-100560~1001.20.8×0.840°811.1190×530
XXQ-160580~1601.50.8×0.840°1915.2225×585
XXQ-2050100~2002.01.5×1.540+5°3023285×665
XXQ-2505150~2502.52.0×2.040+5°4035320×730
XXQ-3005170~3003.02.3×2.340+5°5045.5345×830
XXQ-3205180~3203.22.5×2.340+5°5545.5345×830
XXQ-3505180~3503.42.8×3.040+5°6047345×800

Directional Portable X-ray Flaw Detector (with ceramic X-ray tube)

ModelOutput Voltage
(kV)
Input
(kw)
Focus Size
(mm)
Beam AngleQ235 Max.
Penetration(mm)
Weight of
Generator(kg)
Dimension of
Generator(mm)
XXG-160580~1601.50.8×0.840+5°1914.5225×550
XXG-2005100~2002.02.0×2.040+5°3018285×615
XXG-2505150~2502.52.0×2.040+5°4030.5320×640
XXG-3005170~3003.02.5×2.540+5°5036.5345×670
XXG-3505180~3503.52.5×2.540+5°6038345×670

XXQ-3005

XXQ-3005

about us.jpg

Aolong Group is a high-tech private enterprise with more than 50 years history and has powerful comprehensive technology strength. Aolong Group is not only the professional developer and manufacturer for radiograpny equipment and material testing instrument, but also the supplier of the application solution for the inspecting instrument.

Dandong Aolong Radiative Instrument Group Co.,Ltd. occupies 30 thousand square meters, and the construction area is 17 thousand square meters, owning international modern advanced manufacturing conditions and research, manufacture and test facilities. We are the leading radiography manufacturer and service application provider.

 

Aolong Certificate

ISO9000 International quality system certificate

ISO14001 International environment system certificate

DHSAS18001 International career health & safety management system certificate

CE certificate

发货.jpg

Packing details

Each product will be packed in cartons or wooden cases (we also accept customers' demands)

Delivery time

1. For sample order, 3-5 working days

2. For mass production, 5-7 weeks (It also depends on the order quantity and design)


Download
Get the latest price? We'll respond as soon as possible(within 12 hours)

Privacy policy

close left right